INSTRUMENT CLUSTER INSPECTION
id092200800400
Speedometer
Using the input/output check mode
1. Inspect the speedometer by setting it to check code 12 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
Using a speedometer tester
1. Adjust the tire pressure to the specification.
2. Using a speedometer tester, verify that the tester reading is as indicated in the table below.
Speedometer tester indication (km/h) |
Allowable range (km/h) |
||
---|---|---|---|
Except L3 Turbo |
L3 Turbo |
||
Australisan, European (L.H.D.) specs. |
General (L.H.D. R.H.D.) specs. |
||
20
|
20—25
|
17—23
|
20—26
|
40
|
40—45
|
38—43
|
41—47
|
60
|
60—66
|
57—63
|
61—68
|
80
|
81—87
|
77—83
|
82—89
|
100
|
101—108
|
97—103
|
102—110
|
120
|
121—129
|
116—124
|
123—131
|
140
|
142—149
|
136—144
|
144—152
|
U.K. specs.
Speedometer tester indication (mph) |
Allowable range (mph) |
|
---|---|---|
Except L3 Turbo |
L3 Turbo |
|
10
|
10—14
|
10—14
|
20
|
20—23
|
20—24
|
30
|
30—34
|
30—35
|
40
|
40—44
|
41—45
|
50
|
50—55
|
51—56
|
60
|
60—65
|
61—67
|
70
|
70—76
|
72—77
|
80
|
81—86
|
82—88
|
3. Verify that the speedometer reading is within the range indicated in the table.
Tachometer
Using the input/output check mode
1. Inspect the tachometer by setting it to check code 13 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
Using M-MDS or external diagnostic equipment
1. Connect the M-MDS to the DLC-2.
am3zzw00001959
|
2. Compare the data monitor item (RPM) with the tachometer indication.
Fuel gauge
1. Inspect the fuel gauge by setting it to check code 23 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
Water temperature gauge
1. Inspect the water temperature gauge by setting it to check code 25 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)