VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR INSPECTION [MZR 2.0, MZR 2.5]
id0113d2803000
Operation Inspection
1. Remove the air hose. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR 2.0, MZR 2.5].)
2. Disconnect the vacuum hose from the variable intake air shutter valve actuator.
am3zzw00012021
|
3. Connect a vacuum pump to the variable intake air shutter valve actuator.
4. Check if the rod operates correctly as stated in the table when a gradual negative pressure is applied to the variable intake air shutter valve actuator.
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Below –2.7 {–20, –0.8}
|
Not operate
|
Above –33.4 {–251, –9.86}
|
Fully pulled
|