AFTER SERVICE PRECAUTION [SKYACTIV-G 2.0]
id0114z5801900
Fuel Leakage Inspection
Using M-MDS
1. Connect the M-MDS to the DLC-2.
am3zzw00012097
|
2. Switch the ignition to ON.
3. Using the simulation function “FP”, start the fuel pump. (See ON-BOARD DIAGNOSTIC TEST [SKYACTIV-G 2.0].)
4. Verify that there is no fuel leakage from the pressurized parts.
5. In the case of fuel leakage, replace the following components and then recheck using the fuel leakage checking procedure.
Without using M-MDS
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)
2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)
3. Remove the fuel pump relay.
am3zzw00012098
|
4. Using a jumper wire, short fuel pump relay terminals C and D in the relay and fuse block.
am6zzw00000280
|
5. Connect the negative battery cable and operate the fuel pump. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)
6. Verify that there is no fuel leakage from the pressurized parts.
7. In the case of fuel leakage, replace the following components and then recheck using the fuel leakage checking procedure.