EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR INSPECTION [MZR-CD 2.2]
id0140f2446200
Resistance Inspection
1. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR-CD 2.2].)
2. Remove the battery and battery tray. (See BATTERY REMOVAL/INSTALLATION [MZR-CD 2.2].)
3. Disconnect the exhaust gas pressure sensor/exhaust gas pressure correction temperature sensor connector.
4. Remove the exhaust gas pressure sensor/exhaust gas pressure correction temperature sensor. (See EXHAUST GAS PRESSURE SENSOR/EXHAUST GAS PRESSURE CORRECTION TEMPERATURE SENSOR REMOVAL/INSTALLATION [MZR-CD 2.2].)
5. Place the exhaust gas pressure sensor/exhaust gas pressure correction temperature sensor in water with a thermometer, and heat the water gradually.
6. Measure the resistance between exhaust gas pressure correction temperature sensor terminals A and B.
am3zzw00011591
|
Specification
Water temperature (°C {°F}) |
Resistance (kilohms) |
---|---|
20 {68}
|
2.21—2.69
|
80 {176}
|
0.29—0.35
|