DTC P0743:00 [DJVA-EL]
id0502l1822200
DTC P0743:00 |
TCC solenoid short to GND |
---|---|
DETECTION CONDITION
|
• Condition: TCC solenoid signal not operating while TCM is normal
• Status: Detects short to GND in TCC solenoid system
• Period: Confirmed 1 time in 0.5 s or more
Diagnostic support note
• The AT warning light illuminates if the TCM detects the above malfunction condition during the first drive cycle.
• PENDING CODE is not available.
• The DTC is stored in the TCM memory.
|
POSSIBLE CAUSE
|
• Coupler component connector or terminal malfunction
• Short to GND in wiring harness for coupler component terminal J and TCM terminal A16
• Short to power supply in wiring harness for coupler component terminal J and TCM terminal A16
• TCM conneCtor or terminal malfunction
• Open circuit in wiring harness for coupler component terminal J and TCM terminal A16
• TCC Solenoid malfunction
• TCM malfunction
|
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY RELATED REPAIR INFORMATION AVAILABILITY
• Verify related service information availability.
• Is any related repair information available?
|
Yes
|
Perform repair or diagnosis according to the available repair information.
• If the vehicle is not repaired, go to the next step.
|
No
|
Go to the next step.
|
||
2
|
INSPECT COUPLER COMPONENT CONNECTOR FOR POOR CONNECTION
• Switch the ignition to OFF.
• Disconnect the coupler component connector.
• Inspect for poor connection (such as damaged/pulled-out pins, corrosion)
• Is there any malfunction?
|
Yes
|
Repair or replace the terminal, then go to Step 8.
|
No
|
Go to the next step.
|
||
3
|
INSPECT TCC SOLENOID CIRCUIT FOR SHORT TO GND
• Switch the ignition to OFF.
• Inspect for continuity between the coupler component terminal J (wiring harness-side) and body GND.
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for a possible short to GND, then go to Step 8.
|
No
|
Go to the next step.
|
||
4
|
INSPECT TCC SOLENOID CIRCUIT FOR SHORT TO POWER SUPPLY
• Switch the ignition to ON (Engine off).
• Measure the voltage between the coupler component terminal J (wiring harness-side) and body GND.
• Is the voltage B+?
|
Yes
|
Repair or replace the wiring harness for a possible short to power supply, then go to Step 8.
|
No
|
Go to the next step.
|
||
5
|
INSPECT TCM CONNECTOR FOR POOR CONNECTION
• Switch the ignition to OFF.
• Disconnect the TCM connector.
• Inspect for poor connection (such as damaged/pulled-out pins, corrosion)
• Is there any malfunction?
|
Yes
|
Repair or replace the terminal, then go to the Step 8.
|
No
|
Go to the next step.
|
||
6
|
INSPECT TCC SOLENOID CIRCUIT FOR OPEN CIRCUIT
• Switch the ignition to OFF.
• Inspect for continuity between the coupler component terminal J (wiring harness-side) and TCM terminal A16 (wiring harness-side)
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness for a possible open circuit, then go to the Step 8.
|
||
7
|
INSPECT TCC SOLENOID
• Inspect the TCC solenoid.
• Is there any malfunction?
|
Yes
|
Perform the following procedure, then go to next step.
1. Replace the CVT.
2. Perform oil pressure sensor learning.
(See TCM LEARNING [DJVA-EL].)
|
No
|
Go to the next step.
|
||
8
|
VERIFY DTC TROUBLESHOOTING COMPLETED
• Make sure to reconnect all the disconnected connectors.
• Clear the DTC using the M-MDS.
• Perform the following procedure to ensure that the DTC has been resolved:
• Is the same DTC present?
|
Yes
|
Perform the following procedure, then go to next step.
1. Replace the TCM.
2. Perform TCM learning.
(See TCM LEARNING [DJVA-EL].)
|
No
|
Go to the next step.
|
||
9
|
VERIFY NO DTCs ARE PRESENT
• Perform the “Reading DTCs Procedure”.
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|