NO.2 MIL ILLUMINATES [MZR-CD 2.2]
id0103f3800800
2 |
MIL ILLUMINATES |
---|---|
DESCRIPTION
|
• MIL illuminates incorrectly.
|
POSSIBLE CAUSE
|
• MIL illuminates for emission-related concern (DTC is stored in PCM)
• Instrument cluster malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
RESULTS |
ACTION |
---|---|---|---|
1
|
Retrieve any PCM DTCs using the M-MDS.
Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See DTC TABLE [MZR-CD 2.2].)
|
No
|
Inspect the instrument cluster operation.
Repair or replace the malfunctioning part according to the inspection results.
|
||
2
|
Verify test results.
• If normal, return to the diagnostic index to service any additional symptoms.
• If the malfunction remains, inspect the related Service Information and perform the repair or diagnosis.
|