VARIABLE TUMBLE SOLENOID VALVE INSPECTION [MZR 1.8, MZR 2.0, MZR 2.5]
id0113d0802900
Airflow Inspection
1. Disconnect the negative battery cable.
2. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [MZR 1.8, MZR 2.0, MZR 2.5].)
3. Remove the variable tumble solenoid valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR 1.8, MZR 2.0, MZR 2.5].)
4. Inspect airflow between the ports under the following conditions.
am6zzw00005679
|
MZR 1.8
am6zzw00005680
|
MZR 2.0, MZR 2.5