VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR INSPECTION [MZR 2.0, MZR 2.5]
id0113d08030d2
Operation Inspection
1. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [MZR 1.8, MZR 2.0, MZR 2.5].)
2. Remove the air hose. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR 1.8, MZR 2.0, MZR 2.5].)
3. Disconnect the vacuum hose from the variable intake air shutter valve actuator.
am6zzw00005170
|
4. Connect a vacuum pump to the variable intake air shutter valve actuator.
5. Check if the rod operates correctly as stated in the table when a gradual negative pressure is applied to the variable intake air shutter valve actuator.
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Below –2.7 {–21, –0.9}
|
No operate
|
Above –33.4 {–251, –9.89}
|
Fully pulled
|