SELECTOR LEVER COMPONENT INSPECTION


id051800800600

Caution
•  Water or foreign objects entering the connector can cause a poor connection or corrosion. Be sure not to drop water or foreign objects on the connector when disconnecting it.

1.  Disconnect the negative battery cable.

2.  Remove the selector lever component. (See AUTOMATIC TRANSAXLE SHIFT MECHANISM REMOVAL/INSTALLATION.)

3.  Verify that the continuity is as indicated in the table.

am6zzw00004947

•  If there is any malfunction, replace the selector lever component. (See AUTOMATIC TRANSAXLE SHIFT MECHANISM REMOVAL/INSTALLATION.)