NO. 6 INSTRUMENT CLUSTER ILLUMINATION DOES NOT ILLUMINATE [INSTRUMENT CLUSTER]
id0903d5807900
6 |
Instrument cluster illumination does not illuminate |
---|---|
POSSIBLE CAUSE
|
• Instrument cluster malfunction
• Connector or pin malfunction
• TNS related parts malfunction (relay, switch, wiring harnesses)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Turn the light switch to the TNS position.
• Does the instrument cluster illumination turn on?
|
Yes
|
Troubleshooting completed.
|
No
|
Go to the next step.
|
||
2
|
• Turn the light switch to the TNS position.
• Does the TNS turn on?
|
Yes
|
Go to the next step.
|
No
|
Inspect and repair the following TNS related parts and wiring harness.
|
||
3
|
• Switch the ignition to off.
• Remove the instrument cluster.
• Disconnect the instrument cluster connector.
• Turn the light switch to the TNS position.
• Inspect the voltage instrument cluster wiring harness-side connector terminal 2K.
• Is the voltage B+?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness for open between BCM and instrument cluster terminal 2K.
|
||
4
|
• Switch the ignition to off.
• Inspect the instrument cluster connector terminals for poor connection (such as damaged/pulled-out pins, and corrosion).
• Are the terminals normal?
|
Yes
|
Replace the instrument cluster.
|
No
|
Repair or replace the terminal.
|