ALL SWITCH/DIAL OPERATION DOES NOT RESPOND [FULL-AUTO AIR CONDITIONER]
id0703c1005400
DESCRIPTION
|
• All switch/dial operation of climate control unit does not respond
• Indicator light of climate control unit does not turn on
|
POSSIBLE CAUSE
|
• Open circuit or short to ground in wiring harness between climate control unit terminal 1X and front body control module (FBCM) terminal 1C
• Open circuit or short to power supply in wiring harness between climate control unit terminal 1G and body ground
• Ground point floating, bad contact
• Climate control unit malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1*
|
INSPECT FRONT CLIMATE CONTROL UNIT IG2 SIGNAL
• Switch the ignition ON (engine off or on).
• Measure the voltage at the following terminals (wiring harness-side):
• Is the voltage B+?
|
Yes
|
Go to the next step.
|
No
|
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and front body control module (FBCM) terminal.
If there is a common connector:
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection.
• Repair or replace the malfunctioning part.
If there is no common connector:
• Repair or replace the wiring harness.
Go to Step 3.
|
||
2*
|
INSPECT FRONT CLIMATE CONTROL UNIT GND SIGNAL
• Measure the voltage at the following terminals (wiring harness-side):
• Is the voltage 0 V?
|
Yes
|
Replace the climate control unit, then go to the next step.
|
No
|
Refer to the wiring diagram and verify if there is a common connector between the climate control unit terminal and ground point.
If there is a common connector:
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection.
• Repair or replace the malfunctioning part.
If there is no common connector:
• Repair or replace the wiring harness.
Go to the next step.
|
||
3
|
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Do the related parts operate according to the switch/dial operation of the climate control unit?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|