AIRFLOW MODE ACTUATOR INSPECTION
id074000801700
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the glove compartment. (See GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
3. Remove the airflow mode actuator. (See AIRFLOW MODE ACTUATOR REMOVAL.) (See AIRFLOW MODE ACTUATOR INSTALLATION.)
4. Apply battery positive voltage and connect the ground to the airflow mode actuator terminals as indicated in the table below and verify the operation condition.
|
Terminal |
Airflow mode actuator operation |
|
|---|---|---|
|
D |
F |
|
|
B+
|
Ground
|
DEFROSTER → VENT
|
|
Ground
|
B+
|
VENT → DEFROSTER
|
am6xuw00012226
|
5. Verify that the resistance between terminals B and C, C and A matches the airflow mode actuator operation as shown in the graph.
am6xuw00008627
|