DTC
|
B2449
|
Glow plug circuit short to ground
|
|---|---|---|
|
B2450
|
Glow plug circuit open
|
|
|
DETECTION CONDITION |
• CPU detects malfunction in glow plug circuit
|
|
|
POSSIBLE CAUSE |
• Water heater unit malfunction
|
|
Diagnostic procedure
|
STEP
|
INSPECTION
|
ACTION
|
|
|---|---|---|---|
|
1
|
INSPECT WATER HEATER UNIT
• Replace the water heater unit. (See WATER HEATER UNIT REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)
• Perform the Combustion Test. (SeeKOEO Self Test/Combustion Test.)
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC troubleshooting.
|
|
No
|
Troubleshooting completed.
|
||