DTC TABLE [MANUAL AIR CONDITIONER]
id0702c2801700
DTC |
Warning lamp |
Malfunction location |
Detected condition |
Fail safe |
Drive cycle |
Self test type*1 |
Memory function |
Page |
---|---|---|---|---|---|---|---|---|
B1086:71
|
—
|
Airflow mode actuator
|
Motor lock
|
X
|
—
|
C
|
X
|
|
B13AA:71
|
—
|
Air mix actuator
|
Motor lock
|
X
|
—
|
C
|
X
|
|
B13AB:11
|
—
|
Air mix actuator (potentiometer)
|
Circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B13AB:13
|
—
|
Circuit open
|
X
|
—
|
C, D
|
X
|
||
B1B71:11
|
—
|
Evaporator temperature sensor
|
Circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B1B71:13
|
—
|
Circuit open
|
X
|
—
|
C, D
|
X
|
||
B1C1C:11
|
—
|
Airflow mode actuator (potentiometer)
|
Circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B1C1C:13
|
—
|
Circuit open
|
X
|
—
|
C, D
|
X
|
||
U0010:88
|
—
|
CAN communication system
|
Bus off
|
X
|
—
|
C, D
|
X
|
|
U0155:00
|
—
|
Lost communication with instrument cluster
|
No sub type information
|
X
|
—
|
C
|
X
|
|
U0423:68
|
—
|
Invalid date received from Instrument cluster
|
Event information
|
X
|
—
|
C, D
|
X
|
|
U200D:11
|
—
|
Climate control unit circuit voltage (+5V)
|
Circuit short to ground
|
—
|
—
|
C, D
|
X
|
|
U2300:54
|
—
|
Configuration error
|
Data not received
|
X
|
—
|
C, D
|
X
|
|
U2300:55
|
—
|
Not configured
|
X
|
—
|
C, D
|
—
|
||
U2300:56
|
—
|
Ineffective/non-interchangeable data read
|
X
|
—
|
C, D
|
X
|
||
U2300:64
|
—
|
Error value read
|
X
|
—
|
C, D
|
X
|
||
U3003:16
|
—
|
Climate control unit power supply voltage
|
Power supply voltage decreases (9.98 V or less)
|
—
|
—
|
C, D
|
X
|
|
U3003:17
|
—
|
Climate control unit power supply voltage
|
Power supply voltage increases (16.21 V or more)
|
—
|
—
|
C, D
|
X
|