NO.4 NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [MANUAL AIR CONDITIONER]
id0702c2812400
4
|
No temperature control with climate control unit
|
DESCRIPTION
|
• Temperature does not change when operating temperature dial
• Malfunction in A/C unit and/or climate control unit air mix system
• Malfunction in air mix actuator or related wiring harness
|
POSSIBLE CAUSE
|
• A/C unit air mix link, air mix crank, air mix rod, malfunction
• Climate control unit rack-and-pinion, malfunction
• A/C unit air mix door malfunction
• Heater piping malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT COOLANT TEMPERATURE
• Is the coolant sufficiently warmed up?
|
Yes
|
Go to the next step.
|
No
|
Warm up the engine, then go to Step 20.
|
||
2*
|
INSPECT CLIMATE CONTROL UNIT POWER SUPPLY FUSE FOR B+ SIGNAL
• Is the climate control unit power supply fuse for B+ signal normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect for short to ground in blown fuse circuit.
Repair or replace as necessary.
Install appropriate amperage fuse, then go to Step 20.
|
||
3*
|
INSPECT TO SEE WHETHER MALFUNCTION (OPEN CIRCUIT) IS IN POWER SUPPLY SIGNAL WIRING HARNESS (BETWEEN FUSE BLOCK AND CLIMATE CONTROL UNIT) OR ELSEWHERE.
• Disconnect the climate control unit connector.
• Switch the ignition ON (engine off or on).
• Measure voltage at climate control unit terminal B (wiring harness-side).
• Is the voltage approx. 12V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between fuse block terminal and climate control unit terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness which has an open circuit.
Go to Step 20.
|
||
4*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND GROUND) OR ELSEWHERE
• Climate control unit connector disconnected.
• Verify that continuity between climate control unit terminal A (wiring harness-side) and ground.
• Is the continuity?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and ground.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 20.
|
||
5*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR AIR MIX ACTUATOR
• Reconnect the disconnected climate control unit connector.
• Switch the ignition ON (engine off or on).
• Measure the voltage at climate control unit terminal L when temperature control dial at MAX HOT and MAX COLD.
• Is voltage normal?
|
Yes
|
Go to Step 16.
|
No
|
Go to the next step.
|
||
6*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POSITION SENSOR OR ELSEWHERE
• Switch the ignition ON (engine off or on).
• Measure voltage at climate control unit terminal J when airflow mode change to DEF and VENT.
• Is voltage normal?
|
Yes
|
Go to Step 9.
|
No
|
Go to the next step.
|
||
7*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR SHORT TO POWER SUPPLY OR GROUND) IS IN POSITION SENSOR POWER SUPPLY (CLIMATE CONTROL UNIT TERMINAL G) OR ELSEWHERE
• Switch the ignition ON (engine off or on).
• Measure voltage at climate control unit terminal G.
• Is voltage approx. 5V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator / air mix actuator terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 20.
|
||
8*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR OPEN) IS IN POSITION SENSOR GROUND (CLIMATE CONTROL UNIT TERMINAL K) OR ELSEWHERE
• Measure voltage at climate control unit terminal K.
• Is the voltage below. 1.0V?
|
Yes
|
Go to Step 12.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator / air mix actuator terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 20.
|
||
9
|
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO POWER SUPPLY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE
• Is climate control unit terminal L voltage approx. 12V, at Step 5?
|
Yes
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator / air mix actuator terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness which has a short to power supply.
Go to Step 20.
|
No
|
Go to the next step.
|
||
10*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE
• Switch the ignition off.
• Disconnect the climate control unit and air mix actuator connectors.
• Verify continuity between climate control unit terminal L and air mix actuator terminal F (wiring harness-side).
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal L and air mix actuator terminal F.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 20.
|
||
11*
|
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO GROUND) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR POSITION SENSOR COMMON (POWER SUPPLY OR GROUND) HARNESS
• Climate control unit and air mix actuator connectors disconnected.
• Verify continuity between climate control unit terminal L (wiring harness-side) and ground.
• Is there continuity?
|
Yes
|
Repair wiring harness for short to ground between climate control unit terminal L and air mix actuator terminal F.
Then go to Step 20.
|
No
|
Inspect and repair for open circuit following:
• Between air mix actuator terminal E (L.H.D.) / G (R.H.D.) and junction point to airflow mode actuator (position sensor power supply).
• Between air mix actuator terminal G (L.H.D.) / E (R.H.D.) and junction point to airflow mode actuator (position sensor ground).
Then go to Step 20.
|
||
12*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIR MIX ACTUATOR OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)
• Disconnect the air mix actuator connector.
• Measure voltage at the following terminals of air mix actuator.
L.H.D.
R.H.D.
• Are voltage s as shown below?
|
Yes
|
Go to Step 16.
|
No
|
Go to the next step.
|
||
13*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO POWER SUPPLY BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Air mix actuator connector disconnected.
• Disconnect the climate control unit connector.
• Measure voltage at the following terminals (wiring harness-side) of the climate control unit.
• Are voltages approx. 0V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness which has a short to power supply.
Go to Step 20.
|
||
14*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Air mix actuator connector disconnected.
• Switch the ignition off.
• Verify that continuity at the following terminals (wiring harness-side) between climate control unit and ground.
• Is there continuity?
|
Yes
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness which has a short to ground.
Go to Step 20.
|
No
|
Go to the next step.
|
||
15
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Air mix actuator connector disconnected.
• Switch the ignition off.
• Verify that continuity at the following terminals (wiring harness-side) between climate control unit and air mix actuator.
L.H.D.
R.H.D.
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 20.
|
||
16
|
INSPECT AIR MIX ACTUATOR
• Inspect the air mix actuator.
• Is air mix actuator normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the suspected side air mix actuator.
Then go to 20.
|
||
17
|
INSPECT AIR MIX LINK
• Inspect air mix link.
• Are above items okay?
|
Yes
|
Go to the next step.
|
No
|
Apply grease to links.
If any links are damaged. Replace malfunctioning part.
Then go to Step 20.
|
||
18
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR MIX DOOR ELSEWHERE
• Inspect A/C unit and air mix door.
• Are above items okay?
|
Yes
|
Go to the next step.
|
No
|
Remove the obstruction, or install door in proper position.
If any door are cracked, replace them.
Then go to the next step.
|
||
19
|
INSPECT HEATER LINES
• Inspect heater lines for followings:
• Are above items okay?
|
Yes
|
Replace the climate control unit.
Then go to the next step.
|
No
|
If heater piping connections is loosed, tighten connections with specified torque.
Repair or replace heater piping.
Then go to the next step.
|
||
20
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Does the unit operate in every temperature setting?
|
Yes
|
Trouble shooting completed.
Explain repairs customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step1 if the malfunction recurs.
|