SECURITY AND LOCKS PERSONALIZATION FEATURES SETTING PROCEDURE


id091400112900


Advanced Keyless Entry System


Using M-MDS

1.  Connect the M-MDS to DLC-2.

2.  After the vehicle is identified, select the following items from the initial screen of the M-MDS.

1.  Select the "Module Programming".
2.  Select "Programmable Parameters".

3.  Select menu in the SSU.

4.  Select an item name, and then select option.

M-MDS display

Function

Initial setting

Setting content

Control unit

Advanced keyless function.*1
The advanced keyless entry system and push button start system functions can be disabled.
Enabled.
Enabled. / Disabled.
Start stop unit
Walk Away Lock.
The out-of-area (reception area) type auto lock function can be set.
OFF
Not Adopted. / OFF / ON
Start stop unit
Auto Re-lock Time.
The operation start time of the auto re-lock function can be changed.
30 seconds
Not Adopted. / 30 seconds / 60 seconds / 90 seconds
Start stop unit
Lock Beep Volume.
The keyless beeper volume can be adjusted.
Medium / Off*2
Not Adopted. / Off / Low / Medium / High
Start stop unit

*1  :Because the push button start system function has been disabled, to start the engine press the upper part of the remote transmitter against the center of the push button start.
*2  :The initialization setting varies depending on the market and specification.

Setting method by operation of remote transmitter button

•  The following setting can be changed by operation of the remote transmitter button.

M-MDS display

Function

Initial setting

Setting content

Control unit

Lock Beep Volume.
The keyless beeper volume can be adjusted.
Medium
Off / Low / Medium / High
Start stop unit

•  Change the setting for the keyless beeper volume referring to the following procedure:
Note
•  If any of the following conditions is met during procedure, the setting for changing the keyless beeper volume is finished.
―  The ignition is switched to ACC or ON (engine off or on).
―  The driver's door is closed.
―  The liftgate is open.
―  The remote transmitter operation is not performed for approx. 10 s.
―  The UNLOCK button on the remote transmitter is pressed.
―  A request switch is pressed.
ac5wzw00004612


Using audio unit (with color LCD)


Keyless Entry System


Using M-MDS

1.  Connect the M-MDS to DLC-2.

2.  After the vehicle is identified, select the following items from the initial screen of the M-MDS.

1.  Select the "Module Programming".
2.  Select "Programmable Parameters".

3.  Select menu in the SSU.

4.  Select an item name, and then select option.

M-MDS display

Function

Initial setting

Setting content

Control unit

Advanced keyless function.*1
The keyless entry system and push button start system functions can be disabled.
Enabled.
Enabled. / Disabled.
Start stop unit
Auto Re-lock Time.
The operation start time of the auto re-lock function can be changed.
30 seconds
Not Adopted. / 30 seconds / 60 seconds / 90 seconds
Start stop unit

*1  :Because the push button start system function has been disabled, to start the engine press the upper part of the remote transmitter against the center of the push button start.


Using audio unit (with color LCD)


Power Door Lock System


Using M-MDS

•  For the auto door lock function, refer to the personalization features for the rear body control module (RBCM). (See CONTROL SYSTEM PERSONALIZATION FEATURES SETTING PROCEDURE.)


Setting method by operation of remote transmitter button

•  The following setting can be changed by operation of the remote transmitter button.

Function

Initial setting

Setting content

Control unit

2-step unlocking function.*1
OFF
OFF/ON
Start stop unit

*1  :With 2-step unlocking function.
•  Change the setting for the 2-step unlocking function referring to the following procedure:
Note
•  If any of the following conditions is met during procedure, the setting for changing the keyless beeper volume is finished.
―  The ignition is switched to ACC or ON (engine off or on).
―  The driver's door is closed.
―  The trunk lid is open.
―  The remote transmitter operation is not performed for approx. 10 s.
―  The lock button on the remote transmitter is pressed.
―  A request switch is pressed.