VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [L8, LF, L5]


id0113a0803100

1.  Remove the air hose. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L8, LF, L5].)

2.  Disconnect the vacuum hose from the variable tumble shutter valve actuator.

L8

am6zzw00000204

LF, L5

am6zzw00000220

3.  Connect a vacuum pump to the variable tumble shutter valve actuator.

4.  Apply vacuum and verify that the rod moves.

•  If the rod does not move, replace the intake manifold. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L8, LF, L5].)

Vacuum

kPa {mmHg, inHg}

Rod movement

Below –2.7 {–21, –0.9}
No operate
Above –33.4 {–251, –9.89}
Fully pulled