VARIABLE AIR DUCT (VAD) SHUTTER VALVE INSPECTION [L5]


id0113a5803800

1.  Remove the air cleaner case. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [L8, LF, L5].)

2.  Disconnect the vacuum hose from the VAD shutter valve actuator.

3.  Connect a vacuum pump to the VAD shutter valve actuator.

am6zzw00000209

4.  Apply vacuum and verify that the rod moves.

•  If the rod dose not move, replace the air cleaner.
am6zzw00000210

Vacuum

kPa {mmHg, inHg}

Rod movement

Below –10 {–75, –3.0}
Starts to move
Above –35 {–263, –10.4}
Fully pulled