MAIN RELAY CONTROL OPERATION [13B-MSP]


id0140g1170200

•  When the ignition switch is turned to the ON position, the main relay turns on and power is supplied to sensors and devices.
•  When the ignition switch is turned from on to off, a main relay on command signal is received the main relay turns on and the following actions take place:
1.  Throttle valve control: Fully closed throttle learning function (See DRIVE-BY-WIRE CONTROL OPERATION [13B-MSP].)
2.  Ignition switch off function of the metering oil pump control (See METERING OIL PUMP CONTROL OPERATION [13B-MSP].)
3.  After-cooling function of the electrical fan control (See ELECTRONIC SPARK ADVANCE (ESA) OPERATION [13B-MSP].)
•  When the on request signal from the controls stop, the main relay turns off.