METERING OIL PUMP DRIVER INSPECTION [13B-MSP]
id0140g1790700
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [13B-MSP].)
2. Disconnect the negative battery cable.
3. Disconnect the metering oil pump driver connector.
4. Verify that the resistance is as indicated in the table .
ar8uuw00001608
|
Metering Oil Pump Driver Resistance
Terminal |
Resistance |
---|---|
B—D
C—B
C—F
D—F
|
50—100 kilohm
|
D—A
D—E
|
1 Megohm
|