1. Disconnect the negative battery cable.
2. Discharge the refrigerant from the system. (See REFRIGERANT CHARGING.)
3. Hold the piping block with pliers or a similar tool and loosen the refrigerant pressure switch using a wrench.
4. Remove in the order indicated in the table.
5. Install in the reverse order of removal.
1. Apply compressor oil to the O-ring joints.