FUEL TANK INSPECTION[L3]


id0114a2803200

Note
•  This inspection is for two rollover valves integrated in the fuel tank.

1.  Perform the "Fuel Line Safety Procedure" referring to the BEFORE SERVICE PRECAUTION. (See BEFORE SERVICE PRECAUTION[L3].)

2.  Disconnect the negative battery cable.

3.  Remove the fuel tank. (See FUEL TANK REMOVAL/INSTALLATION[L3].)

4.  Remove the residual fuel.

5.  Install the fuel pump unit. (See FUEL PUMP UNIT REMOVAL/INSTALLATION[L3].)

6.  Plug the fuel pipe, breather pipe and port C of the fuel pump unit.

atraaw00003073

7.  Place the fuel tank in a level position.

8.  Blow through port B and verify that there is airflow from port A.

•  If there is no airflow, replace the fuel tank.

9.  Turn the fuel tank upside-down. Blow through port B and verify that there is no airflow from port A.

atraaw00003074

•  If there is airflow, replace the fuel tank. (See FUEL TANK REMOVAL/INSTALLATION[L3].)