FUEL TANK INSPECTION[L3]
id0114a2803200
1. Perform the "Fuel Line Safety Procedure" referring to the BEFORE SERVICE PRECAUTION. (See BEFORE SERVICE PRECAUTION[L3].)
2. Disconnect the negative battery cable.
3. Remove the fuel tank. (See FUEL TANK REMOVAL/INSTALLATION[L3].)
4. Remove the residual fuel.
5. Install the fuel pump unit. (See FUEL PUMP UNIT REMOVAL/INSTALLATION[L3].)
6. Plug the fuel pipe, breather pipe and port C of the fuel pump unit.
atraaw00003073
|
7. Place the fuel tank in a level position.
8. Blow through port B and verify that there is airflow from port A.
9. Turn the fuel tank upside-down. Blow through port B and verify that there is no airflow from port A.
atraaw00003074
|