NO.39 O/D OFF INDICATOR LIGHT DOES NOT ILLUMINATE WHEN O/D OFF SWITCH IS TURNED TO ON[LA4AX-EL (CD4E)]
id0503a2807600
39 |
O/D OFF indicator light does not illuminate when O/D OFF switch turned to ON |
---|---|
POSSIBLE CAUSE
|
• The malfunction is in the O/D OFF switch
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Do other indicator lights illuminate with the ignition switch at ON?
|
Yes
|
Inspect the meter fuse
|
No
|
Go to the next step
|
||
2
|
• Inspect the O/D OFF switch
• Is the O/D OFF switch normal?
|
Yes
|
Go to the next step
|
No
|
Repair or replace any malfunctioning parts
|
||
3
|
• Inspect the voltage at the following PCM terminal
• O/D OFF indicator light signal
• Is terminal voltage normal?
|
Yes
|
Service as required
|
No
|
Replace the PCM
|
||
4
|
• Inspect the O/D OFF indicator light
• Is the O/D OFF indicator light normal?
|
Yes
|
Inspect for an open circuit or disconnected connector in the wiring harness between the following
• Ignition switch and O/D OFF indicator light
• O/D OFF indicator light and PCM
|
No
|
Repair or replace any malfunctioning parts
|
||
5
|