TRANSAXLE RANGE (TR) SWITCH INSPECTION[GF4AX-EL]
id051703800900
Operation Inspection
1. Verify that the starter operates only with the ignition switch is turned to the START position with the selector lever in P or N position.
2. Verify that the back‐up lights illuminate when shifted to R position with the ignition switch at the ON position.
3. Verify that the positions of the selector lever and the indicator are aligned.
atraaw00001980
|
Continuity Inspection
1. Disconnect the negative battery cable.
2. Remove the battery and battery tray.
3. Disconnect the TR switch connector.
4. Verify that the continuity is as indicated in the table.
atraaw00001981
|
atraaw00001982
|
5. Reinspect for continuity at TR switch.
6. Connect the TR switch connector.
7. Connect the negative battery cable.