TRANSAXLE FLUID TEMPERATURE (TFT) SENSOR INSPECTION[GF4AX-EL]
id051703801000
On‐Vehicle Inspection
1. Disconnect the negative battery cable.
2. Remove the battery and battery tray.
3. Remove the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)
4. Disconnect the coupler component connector.
atraaw00001994
|
5. Measure the resistance between the terminals of the TFT sensor.
atraaw00001995
|
ATF temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
-20 {-4}
|
13.47—17.17
|
0 {32}
|
5.445—6.678
|
20 {68}
|
2.441—2.894
|
40 {104}
|
1.193—1.374
|
60 {140}
|
0.6284—0.7048
|
80 {176}
|
0.3527—0.3865
|
100 {212}
|
0.2091—0.2245
|
120 {248}
|
0.1301—0.1372
|
130 {266}
|
0.1044—0.1090
|
6. Connect the coupler component connector.
7. Install the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)
8. Install the battery tray and battery.
9. Connect the negative battery cable.
Off-Vehicle Inspection
1. Remove the TFT sensor. (See TRANSAXLE FLUID TEMPERATURE (TFT) SENSOR REMOVAL/INSTALLATION[GF4AX-EL].)
atraaw00001996
|
2. Place the TFT sensor and in ATF a thermometer as shown in the figure, and heat the ATF gradually.
3. Measure the resistance between the terminals of the TFT sensor.
atraaw00001997
|
ATF temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
-20 {-4}
|
13.47—17.17
|
0 {32}
|
5.445—6.678
|
20 {68}
|
2.441—2.894
|
40 {104}
|
1.193—1.374
|
60 {140}
|
0.6284—0.7048
|
80 {176}
|
0.3527—0.3865
|
100 {212}
|
0.2091—0.2245
|
120 {248}
|
0.1301—0.1372
|
130 {266}
|
0.1044—0.1090
|
4. Install the TFT sensor. (See TRANSAXLE FLUID TEMPERATURE (TFT) SENSOR REMOVAL/INSTALLATION[GF4AX-EL].)