INPUT/TURBINE SPEED SENSOR INSPECTION[GF4AX-EL]


id051703801200

1.  Disconnect the negative battery cable.

2.  Remove the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)

3.  Disconnect the input/turbine speed sensor connector.

atraaw00001999

4.  Measure the resistance between the input/turbine speed sensor terminals.

atraaw00002000

•  If there is any malfunction, replace the input/turbine speed sensor. (See INPUT/TURBINE SPEED SENSOR REMOVAL/INSTALLATION[GF4AX-EL].)
Resistance
330—390 ohms (ATF temperature: 20 °C {68 °F})

5.  Connect the input/turbine speed sensor connector.

6.  Install the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)

7.  Connect the negative battery cable.