O/D OFF SWITCH INSPECTION[LA4AX-EL (CD4E)]
id051708803200
System Inspection
1. Turn the ignition switch to the ON position.
2. Verify that the O/D OFF indicator light is not illuminated.
3. Depress the O/D OFF switch and verify that the O/D OFF indicator light illuminates.
Voltage Inspection
1. Remove the upper panel from the floor console. (See FLOOR CONSOLE REMOVAL/INSTALLATION.)
2. Turn the ignition switch to the ON position.
3. Measure the voltage when the O/D OFF switch is cycled.
atraaw00000734
|
Position |
Terminal |
|
---|---|---|
C |
D |
|
Normal position (V)
|
B+
|
0
|
Depressed position (V)
|
0
|
0
|
4. Install the upper panel to the floor console. (See FLOOR CONSOLE REMOVAL/INSTALLATION.)
Continuity Inspection
1. Disconnect the negative battery cable.
2. Remove the upper panel from the floor console. (See FLOOR CONSOLE REMOVAL/INSTALLATION.)
3. Disconnect the selector lever connector.
atraaw00001802
|
4. Measure the continuity between terminals when the O/D OFF switch is cycled.
atraaw00000828
|
atraaw00000736
|
5. Connect the selector lever connector.
6. Install the upper panel to the floor console. (See FLOOR CONSOLE REMOVAL/INSTALLATION.)
7. Connect the negative battery cable.