EXPANSION VALVE REMOVAL/INSTALLATION
id071100800400
1. Disconnect the negative battery cable.
2. Discharge the refrigerant from the system. (See DISCHARGING AND RECOVERY.)
3. Remove the refrigerant line from the expansion valve.
atraaw00003079
|
4. Remove in the order indicated in the table.
aesffw00000086
|
1
|
Cap
|
2
|
Bolt
|
3
|
Expansion valve (See Expansion Valve Removal Note.)
|
5. Install in the reverse order of removal.
6. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM TESTS.)
Expansion Valve Removal Note
1. Do not allow compressor oil to spill.