STEP
|
INSPECTION
|
RESULTS
|
ACTION
|
1
|
• Inspect following:
-
- Engine coolant level
-
- Coolant leakage
-
- Water and anti-freeze mixture
-
- Radiator condition
-
- Collapsed or restricted radiator hoses
-
- Radiator pressure cap
-
- Overflow system
-
- Fan rotational direction
-
- Fuses
• Are all items okay?
|
Yes
|
Go to the next step.
|
No
|
Service as necessary.
Repeat Step 1.
|
2
|
• Connect WDS or equivalent to DLC-2.
• Turn key to ON (Engine OFF).
• Retrieve any DTCs.
• Is "PASSED" displayed?
|
Yes
|
No DTC is displayed:
• Go to the next step.
|
No
|
DTC is displayed:
• Go to appropriate DTC test.
|
3
|
• Start engine and run it at idle speed.
• Turn A/C switch on.
• Does A/C compressor engage?
|
Yes
|
Go to step 5.
|
No
|
Inspect following and repair or replace as necessary:
• Refrigerant charging amount
• Open circuit between A/C relay and PCM terminal 69
• Seized A/C magnetic clutch
• A/C magnetic clutch malfunction
-
- If all items are okay, Inspect following:
-
• Refrigerant pressure switch operation
-
• Evaporator temperature sensor and A/C amplifier
-
• A/C switch is stuck open.
-
• Open or short circuit between refrigerant pressure switch and PCM terminal 41 (R.H.D.)/C-15 (L.H.D.)
-
• Open circuit of blower motor fan switch and resistor (if blower motor does not operate)
|
4
|
• Start engine and run it at idle speed.
• Turn A/C switch ON.
• Do cooling fan and condenser fan operate?
|
Yes
|
Go to the next step.
|
No
|
Cooling fan motor does not operate:
• Inspect for following:
-
- Cooling fan motor malfunction
-
- Cooling fan motor GND open
-
- Open circuit between cooling fan motor and fan control module
Condenser fan motor does not operate:
• Inspect for following:
-
- Condenser fan motor malfunction
-
- Condenser fan motor GND open
-
- Open circuit between condenser fan motor and fan control module
Both cooling fan and condenser fan do not operate:
• Inspect for following:
-
- Fan control module malfunction
-
- Fan control module GND open
-
- Open circuit between fan control module and cooling fan relay
|
5
|
• Is drive belt okay?
|
Yes
|
Go to the next step.
|
No
|
Replace drive belt.
|
6
|
• Is there any leakage around heater unit in passenger compartment?
|
Yes
|
Inspect and service heater for leakage.
|
No
|
Go to the next step.
|
7
|
• Is there any leakage at coolant hoses and/or radiator?
|
Yes
|
Replace malfunctioning part.
|
No
|
Go to the next step.
|
8
|
• Cool down engine.
• Remove thermostat and inspect operation.
• Is thermostat okay?
|
Yes
|
Engine coolant temperature and thermostat are okay.
Inspect engine block for leakage or blockage.
|
No
|
Access ECT PID on WDS or equivalent.
Inspect both ECT PID and temperature gauge readings.
• If temperature gauge on instrument cluster indicates normal range but ECT PID is not same as temperature gauge reading, inspect ECT sensor.
• If temperature gauge on instrument cluster indicates overheating but ECT PID is normal, inspect temperature gauge and heat gauge unit.
|
9
|
• Verify test results.
-
- If okay, return to diagnostic index to service any additional symptoms.
-
- If malfunction remains, inspect related Service Information and perform repair or diagnosis.
-
• If vehicle is repaired, troubleshooting completed.
-
• If vehicle is not repaired or additional diagnostic information is not available, replace PCM.
|