AR91.40-P-0611-05A Deployment of Emergency Tensioning Retractor Units When No Deployment Device Is Present
AR91.40-P-0611-05A Deployment Of Emergency Tensioning Retractor Units When No Deployment Device Is Present
Use of self-fabricated ignition cable
1. Fabricate ignition cable with a length of 10 m with pressure switch.
2. Attach the 2-pin plug connector to the relevant emergency tensioning retractor unit.
3. Connect ignition cable to battery.
4. Press both pushbuttons simultaneously.
Keep a distance of 10 m for safety.