Manufacturer Code Charts: 1982
The actuation of component A80 (Intelligent servo module for DIRECT SELECT) by control unit N73 (EIS [EZS] control unit) has failed.
Possible cause:
- A80 (Intelligent servo module for DIRECT SELECT)
Affected functions:
- Drive position selection
-------------------------------------------------
Test 1: Remedial action in the event of a fault in the internal mechanical systems of component A80 (Intelligent servo module for DIRECT SELECT)
1. Remedial action in the event of a fault in the internal mechanical systems of component A80 (Intelligent servo module for DIRECT SELECT)
Operation number of operation texts and work units or standard texts and flat rates:27-0641NOTE
- The following tests are to be performed in succession
Test sequence
- Depress brake pedal fully and hold.
- Use the selector lever to engage drive positions R, N and D in succession.
Status of relevant actual value:'Shift lock' function
- 'Shift lock' function:Warning!
Selector lever position
- Current position of actuator motor ISM:Warning!
Question
- Are the listed actual values correctly displayed?
YES
Preconditions
- The listed actual values are correctly displayed.
Possible cause and remedy
- No additional tests are necessary.
- Erase fault memory in control unit ISM
End of test
NO
Preconditions
- The listed actual values are not correctly displayed.
Further procedure
- Perform actuation 'Driving position'.
Continue with button "F2"
Test prerequisite
- Engine OFF
- Apply and hold the brakes.
Continue with button "F2"
Warning!Communication with ECU required.