Operation CHARM: Car repair manuals for everyone.

P2197


The signal of oxygen sensor 1 (cylinder bank 2) is shifted towards 'Lean'. There is a signal above the permissible limit value.
Check component 'G3/3 (Left oxygen sensor upstream of catalytic converter)'.


Test 1: Continue

1.
Check component 'G3/3 (Left oxygen sensor upstream of catalytic converter)' by means of actual value.

- The actual values are OK.

End of test



End of test
Result: Pass