Test 2
TEST 2:Test 2:
Pushbutton Control Unit:
Test Conditions:
Selector Dial: 22°C
Function Button: "c"
Blower: "f"
- Establish condition "mode change" (overlap) by turning temperature dial slowly in upward or downward direction until legroom flaps and center nozzles are open.
Test Results/Observations:
- Monovalve cycling (every 4 to 5 seconds). At temperatures of approx. 22°C.
- Compressor switched on at outside temperatures 22°C.
- Main air flaps open (fresh air).
- Blower starts after approx. 10 seconds.
- Recirculating pump running.