Test 3
TEST 3:Main Air Flap - Closed:
Test Conditions:
Selector Dial: MIN (engaged)
Function Button: "b"
Blower: "AUTOM"
Test Results/Observations:
- Monovalve closed.
- Recirculating pump not running.
- Compressor switched on at outside temperature >2°C.
- Main air flaps closed (approx. 20 % fresh air, 80 % recirculating air).
- Blower running (6.7 amps or 5th stage).