Ignition Coil
Cranking Voltage at least 10 VDC
Ignition System Voltages
terminal 15 to ground battery voltage
(terminal 5 at the diagnostic socket)
between terminal 15 and 1 0 VDC
(terminal 5 and 4 at the diagnostic socket)
between terminal 15 and 31 (on 4 pole plug on switching unit) battery voltage
between terminal 16 and 31 (on 4 pole plug on switching unit) battery voltage
Resistance of Ignition Coil
primary winding (terminal 15 to 1) 0.3 - 0.6 Ohms
secondary winding (terminal 1 to 4) 6 - 15k Ohms
Transmitter Resistance
terminal 7 to 3 500 - 700 Ohms
terminal 7 to ground at least 200k Ohms
terminal 3 to ground at least 200k Ohms
Dwell at terminal TD
at cranking speed 5 - 23°
at 1500 rpm 33 - 51°
at 5000 rpm 45 - 55°