Short Circuit to Ground
The Crash Signal from Component N2/7 (Restraint Systems Control Module) is Implausible : Short Circuit to Positive
Test Voltage Level on Crash Signal Wire
Test requirement
- Fault code ' P2098' present
Test sequence
- Switch off ignition.
- Connect socket box (35-pin) to component N3/10 (ME-SFI control module).
- Connect socket box (126-pin) to component N3/10 (ME-SFI control module).
- (5.7) Pin 7 of 35 <--> Pin 97 of 126 (4.12)
- Switch on ignition.
Specified value
- Voltage <1 V
Question
- Is the measured value okay?
Yes
The measured value is o.k.
Further possible causes of fault
- Fault in control unit AB:Read fault memory of control unit N2/7 (restraint systems control module).
No
The measured value is not o.k.
Possible cause and remedy
- Cable from component N2/7 (restraint systems control module) to component N3/10 (ME-SFI control module)
- Read fault memory from control unit AB and rectify faults.
** End of Test **