P20C4
Heating of component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9) , Power supply (P0161)
Test 1: Check component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9).
1. Check component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9).
Test 1.1: Check component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9) using actual value.
Test 1.2: Test current consumption of heating of component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9).
1.1. Check component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9) using actual value.
Warning!Communication with ECU required.
1.2. Test current consumption of heating of component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9).
Test prerequisite
- The actual value is not o.k.
Test sequence
- Switch off ignition.
- Disconnect coupling 5 at component N3/10 (ME-SFI [ME] control unit).
- Measure direct current with multimeter between ground and socket (N3/10) 5.4
- Switch on ignition.
Warning!Perform the measurement only for a short time so that component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9) does not overheat.Specified value
- Amperage[0.6...3.0] A
Question
- Is the measurement value OK?
YES
The measurement value is OK.Further possible causes of fault
- Signal cable of component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9)
- G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9)
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Voltage supply of component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9)
- Lines to component G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9)
- G3/11 (left O2 sensor, downstream TWC, for cylinders 7-9)
End of test