GF42.31-P-3200A BAS pressure reduction function
GF42.31-P-3200A BAS pressure reduction function
BAS pressure reduction
The BAS release switch (s1) is switched passively. Solenoid valve (y1) is switched off and only creates sufficient brake pressure to correspond to the position of the brake pedal.