Test 3: Test Internal Resistance of Component Actuator Motor
Test internal resistance of component Actuator motor
Test sequence
- Switch off ignition.
- Unplug the socket 3 at component N3/10 (ME-SFI control module).
- (N3/10) 3.38<-->3.52 (N3/10)
Specified value
- Resistor [1...10]
Question: Is the measured value okay?
No
- The measured value is not o.k.
Possible cause and remedy
- Wiring between N3/10 (ME-SFI control module) and M16/7 (Recirculating air flap actuator)
- M16/7 (Recirculating air flap actuator)
Yes
- The measured value is o.k.
**End of test**