Test 4C: Test Terminating Resistor of CAN Element In Control Module N3/10 (ME-SFI Control Module)
Test terminating resistor of CAN element in control module N3/10 (ME-SFI control module)
Test terminating resistor of component N3/10 (ME-SFI control module)
Test sequence
- Switch off ignition.
- Connect socket box to component N3/10 (ME-SFI control module).
- Connector 4 is plugged in at control unit.
- Unplug the socket 4 from the wiring harness at the socket box.
- (4.1) 86<-->87 (4.2)
Specified value
- Resistor [115...125]
Question: Is the measured value okay?
No
- The measured value is not o.k.
Possible cause and remedy
- Control unit N3/10 (ME-SFI control module)
*End of test**
Yes
- The measured value is o.k.
**End of test**