EC415
One or more signals sent from control unit N47-5 (ESP and BAS control module) via the CAN bus is implausible.
Possible cause:
- N47-5 (ESP control unit)
Affected functions:
- CAN Communication
- Automatic transmission Function
-------------------------------------------------
Test 1: Fault in CAN communication with control unit N47-5 (ESP control unit).
Test 2: Fault in CAN communication with control unit N47-5 (ESP and BAS control module).
1. Fault in CAN communication with control unit N47-5 (ESP control unit).
Operation number of operation texts and work units or standard texts and flat rates:27-0641WARNING
- This is not a function error of control module Y3/8n4 (Fully integrated transmission control (VGS) control unit) and does not justify replacement.
Possible cause for the entry of this event code
- Operational fault of component N47-5 (ESP control unit)
Possible measures
- Read out fault memory of control unit N47-5 (ESP control unit).
- Process displayed fault codes in control module N47-5 (ESP control unit).
End of test
2. Fault in CAN communication with control unit N47-5 (ESP and BAS control module).
Operation number of operation texts and work units or standard texts and flat rates:27-0641WARNING
- This is not a function error of control module Y3/8n4 (Fully integrated transmission control (VGS) control unit) and does not justify replacement.
Possible cause for the entry of this event code
- Operational fault of component N47-5 (ESP control unit)
Possible measures
- Read out fault memory of control unit N47-5 (ESP control unit).
- Process displayed fault codes in control module N47-5 (ESP control unit).
End of test