118B00
Component B28/5 (Pressure sensor downstream of air filter) has a plausibility error.
Possible cause:
- B28/5 (Pressure sensor downstream of air filter)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component B28/5 (Pressure sensor downstream of air cleaner).
1. Check component B28/5 (Pressure sensor downstream of air cleaner).
Possible cause and remedy
- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose contact and corrosion..
- Inspect air cleaner for soiling/ replace.
End of test