127A00
The switch for selecting the injector bank in the control unit has a short circuit (injector bank 2).
Possible cause:
- Y76 (Fuel injectors)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check injector bank 2.
1. Check injector bank 2.
Possible cause and remedy
- Check lines between control unit N3/9 (CDI control unit) and component Y76y4 (Fuel injector cylinder 4) as well as connections and connectors for damage, correct fitting, loose contact and corrosion, and repair or replace as necessary.
- Check lines between control unit N3/9 (CDI control unit) and component Y76y5 (Fuel injector cylinder 5) as well as connections and connectors for damage, correct fitting, loose contact and corrosion, and repair or replace as necessary.
- Check lines between control unit N3/9 (CDI control unit) and component Y76y6 (Fuel injector cylinder 6) as well as connections and connectors for damage, correct fitting, loose contact and corrosion, and repair or replace as necessary.
End of test