Test E: The Roof Opening Panel Does Not Open Or Close

PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE


E1-E3:






E3-E5:






E5-E7:






E8-E10:






E11-E12:






E13:






Normal Operation
The roof opening panel module receives voltage on circuit 1173 (BN/OG) when the ignition switch is in the ACC or ON position. The roof opening panel module is grounded through circuit (BK). When the roof opening panel switch is pressed, circuit (BK) and circuit (WH) are connected for open/tilt down or circuit (BK) and circuit (VT) are connected for close/tilt up. The roof opening panel module controls the roof opening panel motor by directing power and ground on circuit (OG) and circuit (RD) to the motor.

Possible Causes
- Fuse(s)
- Circuit 1173 (BN/OG) open
- Circuit 57 (BK) open
- Circuit (DB) open
- Circuit (BK) open
- Circuit (WH) open
- Circuit (VT) open
- Circuit (OG) open or short to ground
- Circuit (RD) open or short to ground
- Roof opening panel switch
- Roof opening panel motor