Operation CHARM: Car repair manuals for everyone.

Component Tests and General Diagnostics


1. Run engine at normal operating temperature and set throttle on high cam on 4-140 engine or on kickdown step on other engines.
2. Connect vacuum gauge to EGR side of load control valve and note reading.
3. Apply a vacuum of at least 6 inches Hg to venturi port of valve. If gauge does not drop to zero, replace valve.