BB25 Check Circuit 499
- Disconnect valve block connector from wire harness.
- Check for continuity between breakout box pins 36 and 60.
- Is continuity present?
YES -- Service circuit 499 (GY/BK).
NO -- Reverify code 29.
NOTE: If other codes are output, service next code.