FF2 Check LH Rear Sensor Indicator Resistance
- Disconnect LH brake anti-lock rear sensor plug.
Sensor Plug Terminals:
- Measure resistance of rear brake anti-lock sensor at sensor plug.
- Is resistance between 800 and 1400 ohms?
YES -- Service circuit 518 or 519.
NO -- Replace LH rear brake anti-lock sensor.