Refrigerant Discharging and Recovery procedure
SPECIAL SERVICE TOOL(S)
1. Prior to recovering the refrigerant system, you must verify the purity of the refrigerant. For additional information, refer to Refrigerant Identification Testing. Identifying Refrigerants
2. Connect the R-134a A/C refrigerant center to the low and high-pressure service gauge port valves.
NOTE: Some R-134a service centers require the use of an A/C manifold gauge set. For additional information, refer to Manifold Gauge Set Connection. Manifold Gauge Set Connection
3. Perform the Refrigerant Discharging and Recovery Procedure.
4. Once the refrigerant center has recovered the vehicle A/C system refrigerant, close the refrigerant center inlet valve (if so equipped). Then switch off the power supply.
5. Allow the vehicle A/C system to remain closed for about two minutes. Observe the system vacuum level as shown on the gauge. If the pressure does not rise, disconnect the recovery station hose(s).
6. If the system pressure rises, repeat steps 2 through 5 until the vacuum level remains stable for two minutes.
7. Carry out the required repairs, then Perform the Evacuation and Charging Procedure. For additional information, refer to Evacuation and Charging. Evacuation and Charging Procedure