Identifying Refrigerants
Delux A/C Refrigerant Analyzer:
SPECIAL SERVICE TOOL(S)
1. Follow the instructions included with the Refrigerant Analyzer to obtain the sample for testing.
NOTE: Prior to recovering or charging the refrigerant system, you must use an A/C refrigerant analyzer to identify gas samples taken directly from the refrigeration system or storage containers.
2. The analyzer will display one of the following:
- R-12 or R-134a if the purity is better than 98% by weight.
- FAIL if neither of the two gases have been identified or if they are not at least 98% pure.
- HC and a horn will sound if the gas detected contains a hydrocarbon (flammable material).
3. Recover the contaminated refrigerant using suitable recovery-only equipment designed for capturing and storing contaminated refrigerant. For additional information, refer to Contaminated Refrigerant Handling. Handling of Contaminated Refrigerants
CAUTION: If contaminated refrigerant is detected, DO NOT recover the refrigerant into your recovery/recycling equipment.