Operation CHARM: Car repair manuals for everyone.

Overhaul

REMOVAL

WARNING: ILLUMINATION BULBS ARE PRESSURIZED AND MAY SHATTER IF IMPROPERLY HANDLED. WEAR EYE PROTECTION WHEN REPLACING ILLUMINATION BULBS.


CAUTION: If gauges are being removed from the cluster assembly, do not remove the gauge pointers. Magnetic gauges cannot be recalibrated.

NOTE:
- Gauges are replaced as assemblies. They are not available individually.
- Do not reuse instrument gauge clips.

1. Remove the instrument cluster; refer to Instrument Panel.







2. Remove the instrument cluster gauge amplifier.







3. Remove the instrument cluster lens and mask assembly.
1 Remove the screws.
2 Remove the instrument cluster lens and mask assembly.







4. Gently remove the gauge assemblies.

NOTE: The side gauge assemblies must be removed before removing the center assembly.

INSTALLATION
1. To install, reverse the removal procedure.